METROLOGIC INSTRUMENTS INC.MetroSelect® Single-LineConfiguration Guide
4CODE TYPES AND DECODE RULES (CONTINUED)UPC/EAN (CONTINUED)³100214* Enable EAN-8.³100204Disable EAN-8.CODE 128³100113* Enable Code 128.³100103Disable
94CODE BYTES USAGE (CONTINUED)ASCII REFERENCE TABLE (CONTINUED)HEX ValueDecimal Value/Code Byte ValueCharacterControl KeyboardEqv3C 060 < less tha
95CODE BYTES USAGE (CONTINUED)ASCII REFERENCE TABLE (CONTINUED)HEX ValueDecimal Value/Code Byte ValueCharacterControl KeyboardEqv5A 090 Z5B 091 [ shi
96CODE BYTES USAGE (CONTINUED)ASCII REFERENCE TABLE (CONTINUED)HEX ValueDecimal Value/Code Byte ValueCharacterControl KeyboardEqv79 121 y7A 122 z7B 1
97CODE BYTES USAGE (CONTINUED)EXTENDED KEY CODE REFERENCE TABLE (CONTINUED)KeyAt ScanCodePS2 ScanCode3151Prefix/Suffix ValueHex = DecimalF5 03H 3FH 2
98MISCELLANEOUS FEATURESCUSTOM DEFAULTSMetrologic manufactures several scanners for OEM applications. Thesescanners may use a different set of defaul
99MISCELLANEOUS FEATURESSERIAL PROGRAM MODEFor Serial Program Mode, all commands must be framed by an STX (02 Hex)and ETX (03 Hex).To recall defaults:
December 2002Printed in the USA 00-02544B
5CODE TYPES AND DECODE RULES (CONTINUED)CODE 39³100111* Enable Code 39.³100101Disable Code 39.³100213Enable MOD 43 Check on Code 39.When enabled, th
6CODE TYPES AND DECODE RULES (CONTINUED)CODE 39 (CONTINUED)³100307* Only allow PARAF codes.³100317Allow Non-PARAF codes.³100312Enable TRI-OPTIC Code.
7CODE TYPES AND DECODE RULES (CONTINUED)2 OF 5 CODES³100115* Enable Interleaved 2 of 5 (ITF).³100105Disable Interleaved 2 of 5 (ITF).³100310Enable MO
8CODE TYPES AND DECODE RULES (CONTINUED)2 OF 5 CODES (CONTINUED)³903400~ ITF Minimum Symbol Length. To specify aminimum number of ITF characters to
9CODE TYPES AND DECODE RULES (CONTINUED)2 OF 5 CODES (CONTINUED)³100313Enable 13 Digit Airline 2 of 5.³100303* Disable 13 Digit Airline 2 of 5.³10031
10CODE TYPES AND DECODE RULES (CONTINUED)CODE 93³100112* Enable Code 93.³100102Disable Code 93.CODE 11³100013Enable Code 11.³100003* Disable Code 11
11CODE TYPES AND DECODE RULES (CONTINUED)TELEPEN³100017Enable Telepen.³100007* Disable Telepen.³100016Enable ALPHA Telepen.³100006* Disable ALPHA Tele
12CODE TYPES AND DECODE RULES (CONTINUED)³200724* Enable MSI Plessey Mod 10 Check Digit.Test MSI Plessey bar codes for a 1 digitModulo 10 check digit
13CODE TYPES AND DECODE RULES (CONTINUED)ADDITIONAL DECODE FEATURES³100011Enable Double BorderRequired/Large Intercharacter Space.³100001* Disable D
14CODE TYPES AND DECODE RULES (CONTINUED)CONFIGURABLE CODE LENGTHSThere are seven bar code lock lengths available. Specific code types can beassigne
15CODE TYPES AND DECODE RULES (CONTINUED)CONFIGURABLE CODE LENGTHS (CONTINUED)³902600~ Code Length Lock #4.³902700~ Code Type Lock #4.³902800~ Code L
16SUPPLEMENTS³101217Enable Two Digit Supplements.³101207* Disable Two Digit Supplements.³101212* Enable Two Digit Redundancy.The scanner will scan the
17SUPPLEMENTS (CONTINUED)³101213Supplements are Required.All UPC/EAN labels that are scanned must have asupplement.³101203* Supplements are not Requi
18SUPPLEMENTS (CONTINUED)³101313Enable 378/379 French SupplementRequirement.³101303* Disable 378/379 French SupplementalRequirement.³101413Enable 414
19SUPPLEMENTS (CONTINUED)³101215Enable UPC # System 5 Requires Supplements.³101205* Disable UPC # System 5 RequiresSupplements.³101000* Enable 2 Di
20SUPPLEMENTS (CONTINUED)³101411Enable Code 128 ‘]C1’ Extended Code Format.Scanner transmits an ‘]C1’ at the beginning of theCode 128 portion of the
21SUPPLEMENTS (CONTINUED)³101214Enable Code ID’s with Supplements.³101204* Disable Code ID’s with Supplements.³118406* Beep Once on Supplements.³1184
22SUPPLEMENTS (CONTINUED)³101316Enable ISBN Re-Formatting.³101306* Disable ISBN Re-Formatting.³101210Disable Supplementals when CodeGate®Button is Pr
23RSS BAR CODE IMPLEMENTATIONMetrologic’s MS9520 Voyager® and MS9540 VoyagerCG® laser scanners nowhave the ability to decode RSS bar codes. This soft
iiLOCATIONS CORPORATE HEADQUARTERS North America Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO90 Coles Road Tel: 856-228-8100Blackwoo
24RSS BAR CODE IMPLEMENTATION (CONTINUED)* Transmit RSS 14Symbology IDDo Not Transmit RSS 14Symbology³114902Symbology Identifier “]e0”is transmitted b
25RSS BAR CODE IMPLEMENTATION (CONTINUED)* Transmit RSS LimitedSymbology IDDo Not Transmit RSSLimited Symbology ID³114905Symbology identifier “]e0”is
26ISBT CODE 128 IMPLEMENTATIONPROGRAMMING-MODE BAR CODESEnable ISBT Code 128 Disable ISBT Code 128³138417 ³138407These bar codes are used to Enable/Di
27ISBT CODE 128 IMPLEMENTATIONCONCATENATION PROGRAM MODE BAR CODESSupported by the MS9500 series only.The following bar codes are used to program vari
28ISBT CODE 128 IMPLEMENTATIONPRE-DEFINED CONCATENATION PROGRAM MODE BAR CODESSupported by the MS9500 series only.The first two barcodes can be used t
29ISBT CODE 128 IMPLEMENTATIONPRE-DEFINED CONCATENATION PROGRAM MODE BAR CODES (CONTINUED)Supported by the MS9500 series only.Product Code + Expiratio
30ISBT CODE 128 IMPLEMENTATIONSupported by the MS9500 series only.The following example demonstrates how to program the User-Defined ISBTidentifiers:A
31MS9500 VOYAGER® & VOYAGERCG® SERIESACTIVATION RANGEUse these bar codes to select infrared (IR sensor activation range for sensingwhen objects ar
32MS9500 VOYAGER® & VOYAGERCG® SERIESCODEGATE® STATUS (CONTINUED)Note: The following functions are not supported by all versions of the MS5145.³11
33MS9500 VOYAGER® & VOYAGERCG® SERIESSAME SYMBOL TIME OUTS (CONTINUED)³818920* 875 msec Same Symbol Time Out.³818930750 msec Same Symbol Time Out.
iiiTABLE OF CONTENTSIntroduction ... 1Bar Code Co
34COMMUNICATIONS³415524Enable Light Pen/Wand Communication.Use this option if scanner should be used in placeof a light pen.³415554* Enable RS-232.Whe
35COMMUNICATIONS (CONTINUED)³999995Load IBM 46xx Defaults.³415504Enable IBM 46xx Communication.Select this option for IBM 46xx SIOC/RS485communicatio
36SCANNER OPERATIONCONFIGURATION MODE OPTIONS³118117Allow Configuration Mode on Power-up.Scanner can only enter MetroSet mode beforeany bar codes are
37SCANNER OPERATION (CONTINUED)REDUNDANT SCANS³301100* 0 Redundant Scans.Requires 1 good decode for a “good scan”.³3011101 Redundant Scan.Requires 2 c
38SCANNER OPERATION (CONTINUED)MISCELLANEOUS DECODE FEATURES³118113* Optional Same Symbol Check.Requires 1 different character betweensuccessive bar c
39SCANNER OPERATION (CONTINUED)LED OPTIONS³118313Flash Green LED if Rescan Allowed.This indicates same symbol timeout has elapsed.³118303* Do Not Flas
40SCANNER OPERATION (CONTINUED)BEEPER OPTIONS (CONTINUED)³318535Optional tone 4.³318525Optional Tone 5.³318515Optional tone 6.³318505No Beep.³118406*
41SCANNER OPERATION (CONTINUED)BEEPER OPTIONS (CONTINUED)³118417Beep on BEL Command.The scanner beeps when it receives a BELcharacter from the host. I
42SCANNER OPERATION (CONTINUED)DATA TRANSMISSION DELAYS (CONTINUED)³918800~ Variable msec Intercharacter Delay.Scan this bar code and a sequence of co
43SCANNER OPERATION (CONTINUED)COMMUNICATION TIMEOUT OPTIONS (CONTINUED)³118413* Beep Before Transmit.Scanner will beep after each label is transmitte
ivTABLE OF CONTENTSCommunications ... 34Scanner OperationCo
44SCANNER OPERATION (CONTINUED)COMMUNICATION TIMEOUT OPTIONS (CONTINUED)³118411Razzberry Tone on Time Out.³118401* No Razzberry Tone on Time Out.HOST
45SCANNER OPERATION (CONTINUED)HOST SCANNER COMMANDS (CONTINUED)³118115Use DTR Scan DisableWhen enabled, the scanner will monitor the DTRinput to dete
46SCANNER OPERATION (CONTINUED)HOST SCANNER COMMANDS (CONTINUED)³118111Transmit “NO READ” if DC2 Activated.³118101* Do Not Transmit “NO READ” if DC2 A
47PREFIXES/SUFFIXESNote: Scan Enter Configuration Mode bar code before trying to set this feature.Please refer to Multi-Code Method on page 2.USER CON
48PREFIXES/SUFFIXES (CONTINUED)USER CONFIGURABLE PREFIXES, ALL DATA (CONTINUED)³904200~ Configurable Prefix #8.Assigns an eighth configurable prefix c
49PREFIXES/SUFFIXES (CONTINUED)USER CONFIGURABLE ID CHARACTERS, CODE SPECIFIC (CONTINUED)‡ Enter configuration mode then scan this bar code followed
50PREFIXES/SUFFIXES (CONTINUED)USER CONFIGURABLE ID CHARACTERS, CODE SPECIFIC (CONTINUED)‡ Enter configuration mode then scan this bar code followed
51PREFIXES/SUFFIXES (CONTINUED)USER CONFIGURABLE ID CHARACTERS, CODE SPECIFIC (CONTINUED)³906600~ Configurable Codabar ID.Enter configuration mode the
52PREFIXES/SUFFIXES (CONTINUED)STANDARD PREFIX CHARACTERS (CONTINUED)³116617Enable UPC Prefix ID.The scanner will transmit a prefix before anyUPC/EAN
53PREFIXES/SUFFIXES (CONTINUED)STANDARD PREFIX CHARACTERS (CONTINUED)³105512Enable Manufacturer ID Prefix.Transmits “METROLOGIC” before all bar codeda
vTABLE OF CONTENTSRS232 (Continued)Baud Rate ... 67
54PREFIXES/SUFFIXES (CONTINUED)STANDARD PREFIX CHARACTERS (CONTINUED)³116111Enable SNI Beetle Mode.³116101* Disable SNI Beetle Mode.³116113Enable Cip
55PREFIXES/SUFFIXES (CONTINUED)STANDARD SUFFIX CHARACTERS (CONTINUED)³116602Disable LF Suffix.The scanner will not transmit a Line Feed aftereach bar
56PREFIXES/SUFFIXES (CONTINUED)LONGITUDINAL REDUNDANCY CHECKA Longitudinal Redundancy Check (LRC) is an error checking character that iscalculated acr
57PREFIXES/SUFFIXES (CONTINUED)USER CONFIGURABLE SUFFIXES, ALL DATANote: Scan the Enter/Exit Configuration mode code before trying to set thisfeature.
58PREFIXES/SUFFIXES (CONTINUED)USER CONFIGURABLE SUFFIXES, ALL DATA (CONTINUED)³905200~ Configured Suffix Character #8Assigns an eighth configurable s
59PREFIXES/SUFFIXES (CONFIGURED)³116701* Disable Newcode Formatting Mode A.³116710Enable Newcode Formatting Mode B.³116700* Disable Newcode Formatting
60CODE FormattingUPC/EAN FORMATTING³107517* Transmit UPC-A Check Digit.³107507Do Not Transmit UPC-A Check Digit.³107516Transmit UPC-E Check Digit.³107
61CODE FORMATTING (CONTINUED)UPC/EAN FORMATTING (CONTINUED)³107514Convert UPC-A to EAN-13.With this option, the scanner converts UPC-A toEAN-13 by tr
62CODE FORMATTING (CONTINUED)UPC/EAN FORMATTING (CONTINUED)³107611* Transmit UPC-A MFR#.³107601Do Not Transmit UPC-A MFR#.³107610* Transmit UPC-A ITEM
63CODE FORMATTING (CONTINUED)CODABAR FORMATTING³107717Transmit Codabar Start/Stop Characters.Transmits Codabar’s Start/stop characters beforeand after
1INTRODUCTIONYour new scanner has been configured at the factory with default settings.Since many host systems have unique formats and protocol requir
64CODE FORMATTING (CONTINUED)CODABAR FORMATTING (CONTINUED)³108006* Transmit Codabar Check Digit.³108016Don’t Transmit Codabar Check Digit.CODE 39 FOR
65CODE FORMATTING (CONTINUED)CODE 11 FORMATTING³107713Transmit Code 11 Check Digit.This bar code will transmit Code 11 checkcharacters when used with
66CODE FORMATTING (CONTINUED)PLESSEY (CONTINUED)³107815Enable UK Plessey Special Format.³107805Disable UK Plessey Special Format.³107711Transmit MSI P
67RS-232³415554* Enable RS232 Mode.When enabled the scanner will work with RS-232 +/-12V serial output.PARITY FEATURESA parity bit is an extra data bi
68RS-232 (CONTINUED)BAUD RATE (CONTINUED)³41588038400 BAUD Rate.³41587019200 BAUD Rate.³41586014400 BAUD Rate.³415850*9600 BAUD Rate³4158404800 BAUD R
69RS-232 (CONTINUED)DATA/STOP BITS³1160138 Data Bits.Number of data bits transmitted for eachcharacter.³116003* 7 Data Bits.³1160141 Stop Bit.³116004*
70RS-232 (CONTINUED)HARDWARE HANDSHAKING (CONTINUED)³124510Invert RTS Polarity (RSV1)+12V = Inactive-12V = Active³124500* Standard RTS Polarity.Use st
71RS-232 (CONTINUED)HARDWARE HANDSHAKING (CONTINUED)³115817Enable DTR Support.When enabled the scanner will stop scanningwhen the Data Terminal Ready
72RS-232 (CONTINUED)SOFTWARE HANDSHAKING (CONTINUED)³115903* Disable ACK/NAK.Do not support ACK/NAK handshaking.³115911Support BEL/CAN in ACK/NAK.When
73KEYBOARDENABLE KEYBOARD EMULATION³999994Load Keyboard Wedge Defaults.Loads default settings for keyboard wedge mode.³5155153Enable Stand-Alone Keybo
2BAR CODE CONFIGURATION METHODS (CONTINUED) Please note that the MS6220 Pulsar® can only be configuredusing the Multi-Code Method.To properly configur
74KEYBOARD (CONTINUED)COUNTRY/SCAN CODE TABLE SELECTS (CONTINUED)³416240Italy Keyboard.Enable Italian keyboard³416230Germany Keyboard.Enable German ke
75KEYBOARD (CONTINUED)KEYBOARD/SYSTEM TYPE³216215* AT Keyboard.If using an AT computer, scan the above.(Includes IBM PS/2 and compatible models50, 55,
76KEYBOARD (CONTINUED)“DUMB” TERMINAL SELECTIONSNote: The following terminals may require custom cables.³316400IBM Terminal Keyboards.³316410Reserved
77KEYBOARD (CONTINUED)SPECIAL KEYBOARD FEATURES³116311Transmit Make Code Only.Not available on all models.³116301* Transmit Make/Break Code.Not availa
78KEYBOARD (CONTINUED)SPECIAL KEYBOARD FEATURES (CONTINUED)³116214Enable auto Detect Mode (AT/PS2).Automatically detects caps lock status.³116204* Di
79KEYBOARD (CONTINUED)SPECIAL KEYBOARD FEATURES (CONTINUED)³116303* Use Extended ASCII To Send Extended KeyCodes.Use extended ASCII characters to sen
80KEYBOARD (CONTINUED)INTERSCAN CODE DELAYS³816580* InterScan Code Delay 800 msec.The time specified represents the amount oftime between individual
81KEYBOARD (CONTINUED)Control Set #1ASCII (HEX) ASCII Control Extended Key00H Null Numeric Keypad + (Plus)01H SOH Num Lock02H STX Down Arrow03H ETX N
82OCIA³415544Enable OCIA Mode.Select this option if communications requiresOCIA (Optically Coupled Interface Adapter). Thehost clocks this serial int
83LIGHT PEN PARAMETERS³415524Enable Light Pen Mode.Select this option if the scanner will be used inplace of a light pen. It provides light pen emulat
3CODE TYPES AND DECODE RULESCode Descriptions with an asterisk define a feature that is set as a functionof standard factory defaults.UPC/EAN³100116*
84LIGHT PEN PARAMETERS (CONTINUED)³116901* Disable Inverted IDLE/Extra Toggle.³116910Enable Pre-Transmit Toggle of RTS Line³116900* Disable Pre-Trans
85LIGHT PEN PARAMETERS (CONTINUED)SET NARROW ELEMENT WIDTH (CONTINUED)³8168820500 µs Narrow Element Width.This transmits at 500 µs Narrow element widt
86IBM 46XX CONFIGURATIONIBM PORT³415504Enable IBM 46xx Communication.Select this option for IBM 46xx SIOC/RS485communications. Not all scanners suppor
87IBM 46XX CONFIGURATION (CONTINUED)IBM RESERVED CODES³317200IBM Reserved #1.³317210IBM Reserved #2.³317220IBM Reserved #3.³317240IBM Reserved #5.
88USB‡ When used with the MS9500 series, the following codes will enablecommunication with an MX009 converter cable.OR‡ If used with an MS5145, these
89USB³117817Enable Barcode ID³117807Disable Barcode ID³119817Enable USB Reserve Code #1³119807Disable USB Reserve Code #1³999973Enable USB Reserve Cod
90CODE BYTES USAGENote: Use Configurable Prefixes, Symbol Length and other features that usethese Code Bytes for configuration, require that the scan
91CODE BYTES USAGE (CONTINUED)RESERVED CODES³999988~ Enable Reserved Code. Contact Metrologic forinformation about this feature.³999987~ Disable Res
92CODE BYTES USAGE (CONTINUED)ASCII REFERENCE TABLEHEX ValueDecimal Value/Code Byte ValueCharacterControl KeyboardEqv00 000 NUL @01 001 SOH A02 002 S
93CODE BYTES USAGE (CONTINUED)ASCII REFERENCE TABLE (CONTINUED)HEX ValueDecimal Value/Code Byte ValueCharacterControl KeyboardEqv1D 029 GS ^1E 030 RS