IS3480 QuantumEQuantumT 3580Fusion 3780Orbit 7120/7180Solaris 7820Quick Start GuideAller à www.honeywellaidc.com pour le français.Vai a www.honeywella
8Note: Scan ALT mode after scanning the appropriate Keyboard Country code. ³116217Enable 3-digit ALT Mode³116716³116706Enable 4-digit ALT Mode Disable
9RS232 Communication Commands³115816RTS/CTS Handshaking On³115914XON/XOFF On³115913ACK/NAK On³1160138 Data Bits
10Power Save ModesScan the following bar codes to have the scanner to enter/exit from various power save modes.³1160141 Stop Bit³316045No Parity³31941
11³319420³319430³118617Laser Off Power SaveLaser and Motor Off Power SavePower Save Mode Always³818600Power Save Mode Never
12Host Scanner CommandsScan the Enable D/E Disable bar code below to disable scanning after the scanner receives an ASCII “D” from the host. Scanning
13Scan the Activate DC2 Character bar code below initiate scanning with the receipt of a DC2 character (^R, 124). Scanning the Transmit Serial Number
14LED OptionsScan the Laser LED Off/Scan LED Off bar code to turn off the laser/scan LED while scanning bar codes. The LEDs continue to illuminate fo
15PrefixScan one of the following bar codes to program your scanner to add or remove a start of text character, or AIM, NCR, or Nixdorf identification
16³107905AIM ID Prefix Off³107901³107911NCR Prefix OnNCR Prefix Off³107917Nixdorf Prefix On
17SuffixScan one of the following bar codes to program your scanner to add or remove a carriage return, line feed, tab, or end of text after each bar
18³116612LF Suffix On³116602LF Suffix Off³116610Tab Suffix On³116600Tab Suffix Off
19User Configurable Prefix/SuffixOne or two prefix or suffix characters can be added and assigned for data transmission. Use one of the codes below w
20Example: To add an asterisk (*) as a prefix, scan the bar codes:1. Enter/Exit Programming2. Configurable Prefix #13. Code Byte 04. Code Byte 45. Cod
21SupplementsScan one of the bar codes below to program your scanner for 2 or 5 digit bar code supplements.³903600Configurable Prefix #2³904500Configu
22³101217³1012072 Digit Supplements Off2 Digit Supplements On³1012165 Digit Supplements On³1012065 Digit Supplements Off
23977 (2 Digit) Supplement Required: Turn on this feature when a 2 digit supplement is required for EAN-13 codes that begin with 977.³101314977 Suppl
24UPC/EAN FormattingScan Convert UPC-A to EAN-13 and a leading zero is transmitted before a UPC-A bar code to convert it to EAN-13.³107514Convert UPC-
25Scan Transmit Lead Zero on UPC-E to transmit a zero before each UPC-E bar code.³107513Transmit Lead Zero on UPC-E³107503Don’t Transmit Lead Zero on
26Scan Transmit UPC-A Number System to transmit the UPC-A leading digit with the bar code data. To transmit just the data, without the leading digit,
27Expand UPC-E to 12 Digits expands the UPC-E code to the 12 digit, UPC-A format.³107515Expand UPC-E to 12 Digits³107505Don’t Expand UPC-E to 12 Digit
1Getting StartedTurn off the computer’s power before connecting the scanner, then power up the computer once the scanner is fully connected.Scanner Ho
28When Code 39 Full ASCII On is scanned, certain character pairs within the bar code symbol will be interpreted as a single character. For example:
29³107517³107507Don’t Transmit UPC-A Check Digits*Transmit UPC-A Check Digits³107516³107506*Don’t Transmit UPC-E Check DigitsTransmit UPC-E Check Digi
30GS1 SymbologyDue to the large spaces commonly found in GS1 DataBar symbologies, it is recommended that you enable GS1 Double Border Required. Scan t
31Host ConfigurationsScan one of the following codes, then scan the Recall Defaults code, to program the scanner for one of the following configuratio
32³84661280³84660030³84660140Verifone® Ruby Terminal DefaultsGilbarco® Terminal DefaultsWincor Nixdorf Terminal Defaults³999998Recall Defaults
33MiscellaneousMinimum Symbol Length specifies the minimum number of characters allowable for non-UPC/EAN bar codes. Scan the Enter/Exit Programming
34Code Bytes ³0³1³3³2
35³6³7³5³4
36³9³8
37ASCII Conversion ChartDec Hex Char Dec Hex Char Dec Hex Char Dec Hex Char Dec Hex Char0 00 NUL261A SUB5234 4784E N10468 h101 SOH271B ESC5335 5794F O
2Connecting the Scanner Serial (RS232)Keyboard Wedgeoptional adapter cableConnect to scanner’s host portConnect to scanner’s host portConnect to scan
38PatentsFor patent information, please refer to www.honeywellaidc.com/patents.Technical AssistanceContact information for technical support, product
39This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopie
40
Honeywell Scanning & Mobility9680 Old Bailes RoadFort Mill, SC 29707www.honeywellaidc.comOmni-QS Rev A05/12
3Recall DefaultsScan Recall Defaults to reset all standard product default settings.³999998Recall Defaults
4Interface SelectionsUSB³4164140³999970³416400USB Keyboard EmulationLoad Integrated Full Speed USB IBM/OEM DefaultsUSB Serial Emulation
5RS232Keyboard WedgeKeyboard CountryScan a bar code to select one of the following keyboard country templates. Refer to your Configuration Guide for
6³416210³416200United KingdomBelgium³416230Germany/Austria³416220France
7ALT ModeUse ALT Mode when bar codes or formatting rules include Extended ASCII data that might not have a direct keyboard equivalent. If your bar co
Comments to this Manuals