8
Figure 5
INSTALLING THE SCANNER TO THE HOST SYSTEM
Integrated USB: Full Speed (MS9524-40 and MS9544-40)
Low Speed HID (MS9524-38 and MS9544-38)
1. Turn off the host system.
2. Connect the 10-pin RJ45 male
connector of the USB cable into the jack
on the Voyager
PDF. You will hear a
‘click’ when the connection is made.
3. Connect the other end of the USB cable
to the host USB port.
4. Turn on the host system.
As a default, the MS9524-38/MS9544-38 leaves the factory with USB
Keyboard Emulation Mode enabled.
For information on configuring the MS9524-38/MS9544-38 for
USB Serial Emulation Mode, please refer to the USB section of the
MetroSelect Single-Line Configuration Guide (MLPN 00-02544).
Plugging the scanner into a port on the host system does not guarantee
that scanned information will be communicated properly to the host
system. Please refer to the MetroSelect Single-Line Configuration Guide
or MetroSet2’s help files for instructions on changing the scanner’s
factory default configuration. The scanner and host system must use the
same communication protocols.
Caution:
To maintain compliance with applicable standards, all circuits connected to the scanner must
meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1.
To maintain compliance with standard CSA-C22.2 No. 60950-1/UL 60950-1 and norm EN/IEC
60950-1, the power source should meet applicable performance requirements for a limited
power source.