MS7120 Orbit® Presentation Laser Scanner Installation and User’s Guide
INTRODUCTION INTRODUCTION Mounting Specifications Optional Wall/Counter Mount Item Description Qty.a. Locking Plate, PN 50-50302 1 b. Base Cover
INSTALLATION RS232, Light Pen Emulation 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin so
INSTALLATION RS485 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS7120. 3. Con
INSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS
INSTALLATION Stand-Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on
INSTALLATION Full Speed or Low Speed USB 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socket on
SCANNER OPERATION Audible Indicators When the MS7120 is in operation, it provides audible feedback to indicate the status of the scanner. Eight s
SCANNER OPERATION Visual Indicators The MS7120 is equipped with a blue and a white LED that indicates the scanner’s state and the status of the cu
14 SCANNER OPERATION Failure Mode Indicators Flashing Blue with One Razzberry Tone This indicates that the scanner has experienced a laser subs
SCANNER OPERATION Depth of Field Specifications* Normal Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 15. MS7120 N
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document
SCANNER OPERATION Depth of Field by Bar Code Element Width* Normal Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F G H J K mm .13 -
SCANNER OPERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F G H J K mm - .15 -
18 TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a customer service representative to preserve the limited wa
19TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces The unit is trying to scan a particular symbology that is not enabled
20 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces The bar code may have been printed incorrectly. Check if it is a chec
21TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution RS232 Only The host is receiving data but the data does not look correct. The scanne
22 DESIGN SPECIFICATIONS MS7120 Operational Light Source: Visible Laser Diode (VLD) @ 650 nm Laser Power: Less than 1 mW average Normal Depth
23DESIGN SPECIFICATIONS MS7120 Electrical Voltage Supply: 5VDC ± 0.25V Operating Power: 0.9 W Standby Power: 0.85 W Operating Current: 180
24 APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER V
25SCANNER CONFIGURATION CONFIGURATION MODES The MS7120* Series scanner has three modes of configuration. Bar Codes The MS7120 can be configur
iiTABLE OF CONTENTS Introduction Product Overview ... 1 Sc
UPGRADING THE FIRMWARE The MS7120 is part of Honeywell’s line of scanners with flash upgradeable firmware. The upgrade process requires, a new firm
SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS7120 scanner interfaces terminate to a 10-pin modular socket. The serial number lab
SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable PN 59-59000x -3 straight Pin Function 1 Shield
SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge PowerLink Cable PN 59-59002x -3 Pin Function 1 Keyboard Cl
REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution
31REGULATORY COMPLIANCE EMC Emissions: FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity: CISPR 24, EN 55024 Note: Immunity performance is n
32 REGULATORY COMPLIANCE Standard Europeo Attenzione Questo e’ un prodotto di classe A. Se usato in vicinanza di residenze private potrebbe causa
33LIMITED WARRANTY Honeywell International Inc. ("HII") warrants its products and optional accessories to be free from defects in mater
34 PATENTS This Honeywell product may be covered by, but is not limited to, one or more of the following U.S. Patents: U.S. Patent No.; 4,960,985
35INDEX A AC ... see power accessories ...2, 3 adapter ...
iiiTABLE OF CONTENTS Scanner Configuration... 25 Configuration
36 INDEX P patents...39 pin assignments cable ...33–34 scanner...
CUSTOMER SUPPORT Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the neares
38 CUSTOMER SUPPORT Product Service and Repair Honeywell International Inc. provides service for all its products through service centers through
Honeywell Scanning & Mobility 90 Coles Road Blackwood, NJ 08012 00-02282 Rev E October 2009
1INTRODUCTION Orbit® is an aggressive, omnidirectional laser bar code scanner ideal for use in retail, convenience, liquor and specialty stores
2 INTRODUCTION Scanner and Accessories BASIC KIT COMPONENTS Part No. Description MS7120 Orbit Presentation Laser Bar Code Scanner 00-02282x MS7
INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part No. Description MVC** RS485 Applications MVC Cable ±12VDC to +5.2VDC ** Contact
INTRODUCTION Scanner Components ITEM NO DESCRIPTION 1 White LED (see page 12) 2 Blue LED (see page 12) 3 Red Output Window (Laser Aperture) 4
INTRODUCTION Caution and Serial Number Labels Figure 3. Labeling Locations on the Bottom of the Scanner and Examples Caution To maintain com
Comments to this Manuals