SYMPTOMS POSSIBLE CAUSE(S) SOLUTION
Unit scans the Configuration is not correct Make sure the scanner is configured
bar code but for keyboard wedge mode - Section
there is no data F of the ScanSelect Guide (MLPN
2186)
Unit scans but Configuration is not correct Make sure that the proper PC type
data is not AT, PS2, XT is selected
correct
verify correct country code and data
formatting are selected
Adjust inter character delay
Unit is Configuration is not correct Increase the inter scan code delay
transmitting setting
each character
twice Adjust whether the F0 break is
transmitted. It may be necessary to
try this in both settings.
Alpha characters Computer is in Caps Lock Enable Caps Lock detect setting of
show as lower mode the scanner to detect whether PC is
case operating in Caps Lock
Everything These characters may not be Try operating the scanner in Alt
works except for supported by that country’s mode
a couple of key look up table
characters