Page 1 - Installation and User’s Guide

METROLOGIC INSTRUMENTS, INC.MS9524/44 VoyagerPDF®Series Single-Line Hand Held Laser ScannerInstallation and User’s Guide2989_Cover_May_2006.qxd 5/3/2

Page 2

6 Figure 3 INSTALLING THE SCANNER TO THE HOST SYSTEM Keyboard Wedge (MS9524-47 and MS9544-47) 1. Turn off the PC. 2. Connect the 10-pin RJ45 mal

Page 3 - ABLE OF CONTENTS

7 Figure 4 INSTALLING THE SCANNER TO THE HOST SYSTEM Stand-Alone Keyboard (MS9524-47 or MS9544-47) 1. Turn off the host system. 2. Connect the

Page 4

8 Figure 5 INSTALLING THE SCANNER TO THE HOST SYSTEM Integrated USB: Full Speed (MS9524-40 and MS9544-40) Low Speed HID (MS9524-38 and MS9544-38)

Page 5 - INTRODUCTION

9 Figure 7 Figure 8 THE POWERLINK CABLE Disconnecting Before removing the cable from the scanner, Metrologic recommends that the power on the ho

Page 6 - SCANNER AND ACCESSORIES

10 HOW TO SCAN Three Modes of Operation Auto Trigger, In-Stand • Auto-triggers while in the stand • Bar code is automatically decoded and trans

Page 7

11 HOW TO SCAN Operator Note: PDF-CodeGate is disabled (by default) in all MS9544 VoyagerPDF units. 1. The auto trigger activates

Page 8 - Figure 1

12 STAND Free Standing Kits #46-46128 a. Stand (MLPN 36-00454)...Qty 1 b. Apron (MLPN 50-50440)...

Page 9 - Figure 2

13 STAND There are two options for assembling the stand. The first option allows the stand to be self-supporting and moved freely or placed anywh

Page 10 - Figure 3

14 STAND Stand Option 2: Hard-mounted to countertop (continued) For use with kits #46-46128, #46-46351 and MS951 Stand Replacements Step 3

Page 11 - Figure 4

15 STAND Wall Mount, Option 1: For Kit #46-46433 or Kit #46-46508 Step 1: Drill two #39 pilot holes 3.00” apart. Step 2: Attach the Wall Mou

Page 12 - Figure 5

Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any for

Page 13 - THE POWERLINK CABLE

16 SCANNER PARTS Item No. Description 1 White LED, see page 18 2 Yellow LED, available on the MS9544 only (see page 18). 3 CodeGate Button, ava

Page 14 - HOW TO SCAN

17 INDICATORS Audible When the VoyagerPDF is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight

Page 15

18 INDICATORS Visual The MS9544 has three LED indicators (blue, white and yellow) located on the head of the scanner. The MS9524 has two LED ind

Page 16

19 INDICATORS Visual Alternating Flashing of Blue and White This indicates the scanner is configuration mode. A razzberry tone indicates that an

Page 17

20 CONFIGURATION MODES The MS9524/44 VoyagerPDF Series has 3 modes of configuration. • Bar Codes VoyagerPDF or VoyagerPDF with CodeGate can be

Page 18 - Figure 22

21 CONFIGURATION MODES 4. During configuration, the motor and laser turn off. YOU CANNOT SCAN A BAR CODE WHILE IN SERIAL CONFIGURATION MODE. 5.

Page 19 - Figure 28

22 CONFIGURATION MODES EXAMPLE #3: The following example shows the events that occur when an invalid bar code is sent. This sample will load the

Page 20 - SCANNER PARTS

23 UPGRADING THE FLASH ROM FIRMWARE The MetroSet2 program is a functional component of Metrologic’s new line of Flash-based scanners. This program

Page 21 - INDICATORS

24 LABELS Every scanner has labels and molded text located on the underside of the unit. The labels and text contain important information such as

Page 22

25 DEPTH OF FIELD MINIMUM BAR CODE ELEMENT WIDTH A B - - E - G H J - mm .13 .15 - - .19 - .25 .33 .53 - mils 5.2 5.7 - - 7.5 - 10 13 21

Page 23

iiTABLE OF CONTENTS Introduction... 1 Scann

Page 24 - CONFIGURATION MODES

26 DEPTH OF FIELD PDF417 MINIMUM BAR CODE ELEMENT WIDTH A B mm .25 .38 - - - - - - - - mils 10 15 - - - - - - -

Page 25

27 IR ACTIVATION Figure 33. Specifications subject to change without notice.

Page 26

28 APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. Scanner Ve

Page 27

29 TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-436-38

Page 28 - MAINTENANCE

30 TROUBLESHOOTING GUIDE Symptoms Possible Causes Solution The unit scans a bar code, but locks up after the first scan and the white LED stays o

Page 29 - DEPTH OF FIELD

31 TROUBLESHOOTING GUIDE Symptoms Possible Causes Solution Alpha characters show as lower case. The computer is in Caps Lock mode. Enable Caps L

Page 30

32 TROUBLESHOOTING GUIDE RS232 Demonstration Program If an RS232 scanner is not communicating with your IBM compatible PC, key in the following B

Page 31 - IR ACTIVATION

33 DESIGN SPECIFICATIONS DESIGN SPECIFICATIONS OPERATIONAL Light Source: Visible Laser Diode 650 nm Laser Power: Less than 1 mW (peak) Depth

Page 32 - APPLICATIONS AND PROTOCOLS

34 DESIGN SPECIFICATIONS DESIGN SPECIFICATIONS ELECTRICAL Input Voltage: 5.0VDC ± 0.25V Power: Operating = 900 mW (typical) Standby = 325 mW (

Page 33 - TROUBLESHOOTING GUIDE

35 DEFAULT SETTINGS Many functions of the scanner can be configured or enabled/disabled. The scanner is shipped from the factory configured to a

Page 34

iiiTABLE OF CONTENTS Upgrading the Flash ROM Firmware... 23 Labels...

Page 35

36 DEFAULT SETTINGS PAR AMETER DEFAULT OCIA RS232LIGHT PEN IBM 46XXKBW USB LASER EMULATION PDF CodeGate Inactive Out-of-Stand *      

Page 36

37 DEFAULT SETTINGS PAR AMETER DEFAULT OCIA RS232LIGHT PEN IBM 46XXKBW USB LASER EMULATION Same symbol rescan timeout 250 msecs      

Page 37 - DESIGN SPECIFICATIONS

38 DEFAULT SETTINGS PARAMETER DEFAULT OCIA RS232LIGHT PEN IBM 46XXKBW USBLASER EMULATION Parity Space    Baud Rate 9600  8 Data Bi

Page 38

39 DEFAULT SETTINGS PAR AMETER DEFAULT OCIA RS232LIGHT PEN IBM 46XXKBW USBLASER EMULATION Bookland   as code 39  as code 39 977 (2 digit)

Page 39 - DEFAULT SETTINGS

40 110SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections MS9524/44-41 RS232C and Light Pen Emulation Pin Function 1 Ground 2 RS232 Trans

Page 40

41 110 SCANNER AND CABLE TERMINATIONS MS9524/44-9 OCIA Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RDATA 5 RDATA Retu

Page 41

42 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) RS232 PowerLink Cable MLPN 53-53000x-3 Pin Function 1 Shield Ground 2

Page 42

43 SCANNER AND CABLE TERMINATIONS Cable Connector Configuration (Host End) Keyboard Wedge PowerLink Cable 53-53002x-3 Pin Function 1 Keyboard Clo

Page 43

44 LIMITED WARRANTY The MS9524/44 series scanners are manufactured by Metrologic at its Blackwood, New Jersey, USA facility and at its Suzhou, Chi

Page 44 - Scanner Pinout Connections

45 LASER AND PRODUCT SAFETY EMC/EMI Notices The following is applicable when the scanner cable is not greater in length than 3 meters (9.8 feet) w

Page 45

1 INTRODUCTION Metrologic’s VoyagerPDF series is a group of single-line, hand-held, laser bar code scanners that have the ability to decode 2D cod

Page 46 - MLPN 53-53020x-3

46 LASER AND PRODUCT SAFETY EMC/EMI Notices The following is applicable when the scanner cable is greater in length than 3 meters (9.8 feet) when

Page 47 - 53-53002x-3

47 LASER AND PRODUCT SAFETY Caution Caution Use of controls or adjustments or performance of procedures other than those specified herein may resu

Page 48 - LIMITED WARRANTY

48 PATENTS Patent Information This METROLOGIC product may be covered by one or more of the following US Patents: US Patent No. 5,260,553; 5,340

Page 49 - LASER AND PRODUCT SAFETY

49 INDEX A AC ... see power accessories ...2, 3 adapter ...

Page 50

50 INDEX S safety...45–47 SELV ...4–8 software... s

Page 52 - PATENTS

May 2006 Version 01 Printed in the USA 00-02989D

Page 53

2 SCANNER AND ACCESSORIES BASIC KIT Part # Description MS9524x or MS9544x VoyagerPDF Series Scanner 00-02544 MetroSelect® Single-Line Configuratio

Page 54

3 SCANNER AND ACCESSORIES OPTIONAL ACCESSORIES Part # Description 53-53213x-N-3 USB Full Speed Cable, Locking Plus-Power™ Type A 2.7 m (9 ft.) coi

Page 55

4 Figure 1 INSTALLING THE SCANNER TO THE HOST SYSTEM RS232, Laser Emulation, and Light Pen (MS9524-14/00/41 or MS9544-14/00/41) 1. Turn off the

Page 56 - 00-02989D

5 Figure 2 INSTALLING THE SCANNER TO THE HOST SYSTEM IBM 46xx and OCIA (MS9524-11/9 and MS9544-11/9) 1. Turn off the host system. 2. Plug the m

Comments to this Manuals