SCANNER OPERATION (CONTINUED)
COMMUNICATION TIMEOUT OPTIONS (CONTINUED)
³118411
Razzberry Tone on Time Out.
³118401
* No Razzberry Tone on Time Out.
HOST SCANNER COMMANDS
³118015
Enable “D/E” Disable Command.
When this option is chosen, the scanner will
disable scanning after it receives an ASCII “D”
from the host device. It will enable scanning when
it receives an ASCII “E”.
³118005
* Disable “D/E” Disable.
Do not monitor D/E commands.
³118211
Enable Z/R type D/E Simulation.
When this option is chosen, the scanner will
disable scanning after it receives an ASCII “Z”
from the host device. It will enable scanning when
it receives an ASCII “R”.
³118201
* No “Z/R” Type “D/E” Simulation.
Do not monitor Z/R commands.
³118014
Enable “F/L” Laser Command.
When enabled, the scanner will turn off the laser
after the scanner receives on ASCII “F” character.
The laser will turn on after it receives an ASCII “L”
character.
³118004
* Disable “F/L” Laser Command.
Do not monitor “F/L” commands.