ISBT CODE 128 IMPLEMENTATION
PROGRAMMING-MODE BAR CODES
Enable ISBT Code 128 Disable ISBT Code 128
³138417 ³138407
These bar codes are used to Enable/Disable a Special Transmit mode as
outlined in section 3.5.2 of the ISBT-128 Specification. This output method
allows the user to confirm independently the accuracy of the Code-128 check
digit.
Enable ISBT Special
Transmit
Disable ISBT Special
Transmit
³138416 ³138406
These bar codes can be used to disable the transmission of the ISBT Code 128
data identifiers. When this option is selected, the first two data characters are
removed from the data stream (ID characters) unless the ISBT bar code scanned
contains the Donation Identification Number identifiers. In this instance only the
first ID character is removed from the Donation ID Number. The second is
regarded as normal data.
Don’t Transmit ISBT ID’s * Transmit ISBT Identifiers
³138415 ³138405
These bar codes are used to convert and transmit the Mode 37,2 check digit
from the flag digits of the Donation Identification Number provided the check digit
is contained in the flag digits. Transmission of the Donation Identification numbe
r
will be the same except for the last two digits, which are converted into a single
check sum character.
Convert Flag Digits to
Mod 37, 2 CD
* Normal Flag Digit
Transmission
³138510 ³138500