ScanVue5
®
Mini Kiosk
User Manual
M37574–01T
Industrial Electronic Engineers, Inc.
23-June-2008 Rev T Page 38
Setup for FTP, QFX, NTP, PRODUCTINFO
ServerType Sets the file host as Windows networking (“SMB”), FTP (“FTP”), or QFX
(“QFX”).
FTPServerIP The IP address of the FTP server in standard IP dotted notation.
QFXPort The IP port to use for QFX communications.
QFXServer The IP address of the QFX server.
QFXTimeout The number of hundredths of a second to wait before timing out on QFX
communications.
NTPHost The IP address of the NTP server to provide the date and time, in
standard IP dotted notation. The date obtained is assumed to be GMT.
NTPTZOffset The number of minutes to offset from GMT for the local time zone.
SloppiHost The IP address of the PRODUCTINFO server in standard IP dotted
notation. Can also be a host name up to 12 characters long.
AlternateSloppiHost
The IP address of the backup PRODUCTINFO server in standard IP
dotted notation. Can also be a host name up to 12 characters long.
If SloppiHost fails to respond to a scan request in 10 seconds, the host
server will automatically switch to the AlternateSloppiHost server and
remain there until either the unit reboots or the server is turned off
SloppiPort The IP port to use when sending product information requests and
listening for connections.
SloppiTimeout The maximum wait time, in hundredths of a second, for an initial
response to a product information query, kept in non–volatile storage.
Product Query configuration
IgnoreAckNak Sets ScanVue to ignore ACK and NACK characters when received at
the beginning of an expected packet. Default is FALSE.
IgnoreResponseChars
Sets ScanVue to ignore the number of characters specified, from 0–255
at the beginning of the response packet to a query; default=0.
QueryPadTo Sets the number of text characters for a barcode query to at least the
specified number of bytes by adding NUL bytes after the query string.
Value is 0 to 64. Default=0. Has no effect if value <= # bytes in
barcode+3
QueryPrefix Up to 198 characters. If set, it is prefixed to all query requests.
SendError Controls whether error messages are sent in response to unknown
messages, mode set commands with improper parameters, etc. The
default is FALSE.
SendResponse Controls whether confirmation messages are returned after setting a
mode’s value.
SendUnitID Controls whether the UnitID string is sent as part of product information
requests. The default is TRUE.
TrivialComm The protocol method to use for product information queries