Metrologic IS3480-00 User Manual Page 56

  • Download
  • Add to my manuals
  • Print
  • Page
    / 114
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 55
ScanVue5
®
Mini Kiosk
User Manual
M37574–01T
Industrial Electronic Engineers, Inc.
23-June-2008 Rev T Page 47
In scanvue.ini, double byte strings can be used for wallpaper but the text must start with
<< instead of < or // instead of /.
For the Demoserve data file (data.dat) on the CD-ROM, the characters |> indicate a Big-
Endian string and |< indicates a Little-Endian string. Note: Demoserve actually sends
the FE FF or FF FE bytes not |> or |<.
A utility program, dmp2gdf, provided on the CD-ROM creates a .gdf (double-byte) font
file from a single byte ASCII font file.
Using Input Devices
Scanvue5 has four optional types of manual input device in addition to the standard
barcode scanner. Each type of manual input device generates message tokens with a
similar message packet structure called EVENTS and thus they are all treated together
in this section.
Activating any of the input devices—barcode scanner, touch screen, keypad, magnetic
stripe reader or push button, causes Scanvue5 to transmit the input data, usually a string
of alphanumeric characters, to the host computer for further action by the server based
application.
Touch Screen
The digital touch panel is organized in a 16 column x 12 row matrix. The LCD screen
resolution is 320 x 240 pixels (¼ VGA). Thus each of the 192 discrete touch areas
formed by the matrix is a 20 x 20 pixel square, which is dimensionally ¼”x ¼” and
defines the maximum resolution of the touch screen. Resolution scaling (increasing the
dimensional size of the discrete touch areas) may be set for each axis independently
down to 1 column x 1 row—in other words where the whole display screen is a single
touch button. Resolution scaling can also be changed dynamically by the users
application. In fact, the internal resolution is changed to be 2:1 for increased sensitivity.
reported position={measured position x vertical (or horiz.) scale}/max. resolution
rounded to the next highest integer.
Factory default setting is at the touch screens highest resolution of 31 x 23 where the top
left corner co-ordinate is y,x = 0,0 and the bottom right corner co-ordinate y,x = 23,31.
Examples of calculations for a 4 x 4 matrix—although this is done internally and the user
will only see the reported position.
@4,4 pos. 1 @4,4 pos. 2 @3,3 pos. 3 @3,3 pos. 4 @2,2 pos. 5 @2,2 pos. 6
x
h=(31x4)/31
= 4
h=(25x4)/31
=3.23 ~ 4
h=(23x4)/31
=2.97 ~3
h=(17x4)/31
=2.19 ~ 3
h=(15x4)/31
h=1.94 ~ 2
h=(9x4)/31
h=1.16 ~ 2
y
v=(23x4)/23
= 4
v=(19x4)/23
=3.31 ~ 4
v=(17x4)/23
=2.96 ~ 3
v=(13x4)/23
=2.26 ~ 3
v=(11x4)/23
=1.91 ~ 2
v=(7x4)/23
=1.57 ~ 2
Page view 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 113 114