Metrologic IS3480-00 User Manual Page 73

  • Download
  • Add to my manuals
  • Print
  • Page
    / 114
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 72
ScanVue5® Mini Kiosk
User Manual
M37574–01T
Industrial Electronic Engineers, Inc.
23-June-2008 RevT Page 64
Note: if both ScanVue5 (LCD) and Scanvue420 (VF) units are used in the same installation , the VF models
should be placed in a different group than the LCD models to prevent graphics images being sent to them as
they do not respond to images and will display a blank screen after the “unavailable….try later” message.
[REDIRECT] Allows specified unit to be redirected to another initialization file
UnitID The Token is the unit’s ID number, and the value is the UNC for
the new initialization file. If ScanVue5
®
recognizes its ID in the list
of IDs, it uses the value to obtain the new .ini file. A list of which
initialization files have been referenced in this process must be
kept so that loops can be detected and terminated.
[CLOCK] Superimposes a real time clock display on the LCD screen
ClockFontFile The full path for the file that contains the required font.
Clock_Fcolor Foreground color for the clock display (0-255).
Clock_Bcolor Background color for the clock display (0-255).
ClockTransparent If set to transparent, there is no text box around the display.
Value=TRUE, clock text box is transparent.
Value=FALSE, clock is in a text box of background color.
ClockHPos Defines the horizontal (column) position of the left side of the clock
display box (in pixels)
The left column pixel is 0 and the right column pixel is 319
ClockVPos Defines the vertical (row) position of the top of the clock display
box (in pixels).
The top row pixel is 0 and the bottom row pixel is 219
ClockFormat Defines the format of the clock display.
Value=0, 12 hour display without AM/PM.
Value=12, 12 hour display with AM/PM.
Value=24, 24 hour display.
ClockUpdateInterval Defines the clock display update interval in seconds. If a multiple
of 60 the seconds display is suppressed.
Value=1 to 59 inclusive, displays count of seconds.
Value=60, seconds display is suppressed.
ScanShowClock Defines if clock display is suppressed during a scan cycle.
Value=TRUE, clock display is on all the time.
Value=FALSE, clock display is suppressed during a scan cycle.
NPTServer Gets the time from a time server.
Value=<IP Address>, IPaddress of the time server
TZOffset Defines local time zone offset in minutes from GMT.
Value=n, n=# minutes difference from Greenwich Mean Time.
US East Coast offset is 300 (minutes) from GMT