Metrologic IS3480-00 User Manual Page 53

  • Download
  • Add to my manuals
  • Print
  • Page
    / 114
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 52
ScanVue5
®
Mini Kiosk
User Manual
M37574–01T
Industrial Electronic Engineers, Inc.
23-June-2008 Rev T Page 44
text values to become permanent, the commit command must also be
issued.
Programmatic Modes
Programmatic modes are for use within another program and cannot be read or set
interactively with UnitConfig or modeset. For example, UnitStatus is a mode used within
the ‘heartbeat’ utility program to report on the status of the unit being read. These
modes may also be used within your own program.
GiveHelpText Appends help text to null MDSQ requests.
Timeout The maximum wait time, in hundredths of a second, for an initial
response to a product information query. Valid for the current
connection only.
UnitStatus Reports on the state and activity of the unit. Returns a single line of
values separated by spaces. Counters restart from zero if maximum
count exceeded or unit is reset. In order the values are:
Number of seconds unit has been running since last reset. Largest
number is 42949672 (~16 months).
A single character indicates the current state of the slideshow. N=no
slideshow loaded; R=slideshow running; L=slideshow being loaded.
Total number of slideshows that have been successfully loaded and
started. Maximum count 65535.
Number of slides defined in current slideshow script. Maximum number
65535. If not running, it is the number in previous show or the current
show that was not able to load slides.
Number of slides successfully loaded. If the show is running this is the
actual number of running slides. If not running, it is the number for the
previous show or the current show that was not able to load slides.
e.g., 160 slides defined, 147 loaded.
Total number of slides displayed since last reset. Maximum value is
4294967295.
Total number of images displayed since last reset. Maximum value is
4294967295 and includes text messages, start up screen, frames from
pushed animations
Number of barcodes scanned since startup. Maximum value is
4294967295 and excludes barcodes scanned while the unit is busy with
another product request.
Number of responses from the host to product info queries. Maximum
value is 4294967295. Includes both positive and negative responses.
Number of times the unit received no response from the server.
Maximum value is 4294967295.
Page view 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 113 114

Comments to this Manuals

No comments